CP_w103_proximityPeDisconnected
CP_w103_proximityPeDisconnected
Alert Information
Charging
warning
<0.01%
Description
The charge port (CP) electronic control unit (ECU) detects that the protective earth connection may be missing.
Potential Impact
Charging does not start.
Set Condition
The CP ECU detects proximity voltage greater than 4.75V for more than 100ms.
Clear Condition
The CP ECU detects proximity voltage in the disconnected range for more than 200ms.