DI_a016_parkRequestByPM
DI_a016_parkRequestByPM
Alert Information
Drive Unit
critical
<0.01%
Description
The pedal monitor (PM) requests that the drive interface (DI) electronic control unit (ECU) shift into a non-torque gear (Park or Neutral) at a low speed.
Potential Impact
The DI ECU shifts to Park without user request.
Set Condition
The DI ECU receives a shift request from the PM when vehicle speed is below 1 mph (1.6 km/h).
Clear Condition
The DI ECU exits Park, 5 seconds elapse in Park, or the accelerator pedal is pressed.