DPB_a033_motorDynamicLimited
DPB_a033_motorDynamicLimited
Alert Information
Other
critical
<0.01%
Description
Motor is in a dynamic limited mode when the system starts up.
Potential Impact
System will be running with full assistant for driver brake request. The motor performance is limited.
Set Condition
The previous operation cycle did not end successfully. The plunger did not park at the sleep position, so the relative plunger position is unknown.
Clear Condition
No issue is detected in current operation cycle. This mode will be existed and the alert is cleaned as soon as the backward boundary has been found.