EPASTP_a093_sctpTsuSingleStaticFail
EPASTP_a093_sctpTsuSingleStaticFail
Alert Information
Other
critical
<0.01%
Description
This alert is reported by the SteeringColumnTorqueProvider_R12 (SCTP) component when 1 TSU sensor fails. Quality of service of the provided torque is other than NOMINAL_FAULT_TOLERANT for at least 400 ms.
Potential Impact
One torque sensor failed but EPAS still can operate normal.
Set Condition
EPAS application steering torque diagnostics detected failure (One TSU sensor).
Clear Condition
Quality of service of the provided torque is NOMINAL_FAULT_TOLERANT.