EPASTS_a096_rppRpsSingleStaticFail
EPASTS_a096_rppRpsSingleStaticFail
Alert Information
Other
critical
<0.01%
Description
This alert is reported by the RotorPositionProvider_R12 (RPP) component when there is 1 RPS sensor failure.
Potential Impact
One rotor position sensor failed but EPAS still can operate normal.
Set Condition
EPAS application diagnostics of rotor position sensor detected failure (single sensor).
Clear Condition
Rotor position sensor QoS is QOS_RPS_NOMINAL_FAULT_TOLERANT for one full motor turn.