EPASTS_a163_tdaPowermoduleTempChecker
EPASTS_a163_tdaPowermoduleTempChecker
Alert Information
Other
critical
<0.01%
Description
This alert is reported by the TemperatureDiagnostics_Actuator_R12 (TDA) component when there is a power module overtemperature. Degradation parameters/estimator shall be checked, if those are correct, HW failure.
Potential Impact
EPAS full loss of assist.
Set Condition
EPAS application actuator temperature diagnostics detected overtemperature (power module).
Clear Condition
If the temperature is below the overtemp threshold, and its qualifier is RELIABLE for long enough.