EPASTS_a170_pmpDcvoltAge
EPASTS_a170_pmpDcvoltAge
Alert Information
Other
critical
<0.01%
Description
This alert is reported by the PlatformModeProvider_R12 (PMP) component when the QualityofService of battery voltage signal is QOS_BVP_ERROR and DcVoltAge tolerance time is elapsed.
Potential Impact
EPAS full loss of assist.
Set Condition
Battery voltage QoS signal is fauly for longer than a tolerated time.
Clear Condition
If QoS of battery voltage signal is valid and DcVoltAge within specified time.