EPASTS_a265_overheatProtect
EPASTS_a265_overheatProtect
Alert Information
Other
critical
<0.01%
Description
This alert is reported when the power ratio (actual power divided by nominal power) is less than 70% [Calibratable] due to overheat protection.
Potential Impact
EPAS assist torque is limited due temperature cause.
Set Condition
EPAS power ratio (actual power divided by nominal power) is less than 60% and the cause is temperature related.
Clear Condition
EPAS power ratio (actual power divided by nominal power) is greater than 70% [Calibratable] or the cause of the current degradation is not temperature related.