EPBL_a126_MotorNVoltLow
EPBL_a126_MotorNVoltLow
Alert Information
Other
critical
<0.01%
Description
Motor negative lead voltage measurement is less than 0.5 volts while inactive.
Potential Impact
Caliper motor or harness may be damaged
Set Condition
The Electronic Parking Brake motor is idle, and the negative lead voltage measurement is lower than 0.5 volts.
Clear Condition
Caliper state machine exits csmState CSM_FAULT