EPBR_a124_calOutOfBounds
EPBR_a124_calOutOfBounds
Alert Information
Other
critical
<0.01%
Description
The 0 drive offset current captured as calibration was higher than expected.
Potential Impact
Caliper, Electronic Parking Brake controller, or harness could be damaged. Components may be damaged by high temperatures
Set Condition
The calibration offset current measured when motor is not being driven was higher than 3.0 amps
Clear Condition
Caliper state machine exits csmState CSM_FAULT