IBST_a026_ecuBistCmdTestFault
IBST_a026_ecuBistCmdTestFault
Alert Information
Other
critical
<0.01%
Description
iBooster (IBST) has detected (contrary to specifications) the Built-In Self-Test (BIST) state machine of system Integrated Circuit (IC) is started by an incorrect BIST command.
Potential Impact
IBST may not operate as expected.
Set Condition
IBST detects the BIST state machine of system IC is started by an incorrect BIST command.
Clear Condition
iBooster can not recover from this condition. iBooster replacement may be required.