IBST_a065_tempSens2ShortToGround
IBST_a065_tempSens2ShortToGround
Alert Information
Other
critical
<0.01%
Description
iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 2 line shorted to ground.
Potential Impact
IBST may not operate as expected.
Set Condition
IBST detects BLM temperature sensor 2 line shorted to ground.
Clear Condition
iBooster can not recover from this condition. iBooster replacement may be required.