IBST_a107_LiPS2PwmLineHigh
IBST_a107_LiPS2PwmLineHigh
Alert Information
Other
critical
<0.01%
Description
iBooster (IBST) detected linear position sensor channel 2 line shorted to supply or interruption of sensor ground.
Potential Impact
IBST may not operate as expected.
Set Condition
IBST detects linear position sensor channel 2 line shorted to supply or interruption of sensor ground.
Clear Condition
iBooster can not recover from this condition. iBooster replacement may be required.