BMS_w035_SW_Isolation
BMS_w035_SW_Isolation
Alert Information
Battery
warning
<0.01%
Description
There is an external or internal isolation alert while pack contactors are closed.
Potential Impact
Inability to charge, drive, or support the low voltage (LV) system
Set Condition
The BMS detects that isolation is below the minimum threshold while contactors are closed.
Clear Condition
Isolation restores to the nominal threshold.