DPB_a039_plungerCircuitPressLow
DPB_a039_plungerCircuitPressLow
Alert Information
Other
critical
<0.01%
Description
Pressure in plunger circuit is too low.
Potential Impact
System will request Hydraulic Boost Compensation when driver pressed the brake pedal.
Set Condition
A too low pressure alert occurs, if the actual pressure is much lower than the target pressure.
Clear Condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.