DPB_a094_ecuClockTestFault
DPB_a094_ecuClockTestFault
Alert Information
Other
critical
<0.01%
Description
Clockin monitor of system IC reports wrong clockin alert status to uC.
Potential Impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Set Condition
Erroneous safety logic (The clockin monitor of the system IC reports wrong clockin alert status to the uC). This alert is logged if the feedback to the uC does not show the expected clockin alert state.
Clear Condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.