DPB_a109_GTMTbuMonError
DPB_a109_GTMTbuMonError
Alert Information
Other
critical
<0.01%
Description
GTM reference frequency error.
Potential Impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Set Condition
Clock signal to GTM peripheral or system timer is faulty. The time passed in the sytem timer is compared with the time passed in GTM peripheral.
Clear Condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.