DPB_a137_ASICOvercurrentOnWRHS
DPB_a137_ASICOvercurrentOnWRHS
Alert Information
Other
critical
<0.01%
Description
On the system ASIC an overcurrent event occured on WRHS.
Potential Impact
System will be running with full assistant for driver brake request.
Set Condition
Overcurrent was detected. Overcurrent bit of ASIC is checked and the GPIO is switched off for certain seconds.
Clear Condition
No issue is detected in current operation cycle.