DPB_a266_RPSNvMReadFault
DPB_a266_RPSNvMReadFault
Alert Information
Other
critical
<0.01%
Description
Reading of rotor position calibration data from NvM failed.
Potential Impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Set Condition
Defect NVM or rotor position sensor calibration was not done successfully (new ECU).
Clear Condition
No issue is detected in current operation cycle.