EPASTP_a036_sbcmSbcBistFailed
EPASTP_a036_sbcmSbcBistFailed
Alert Information
Other
critical
<0.01%
Description
This alert is reported by the SystemBasisChipManager_A8140x (SBCM) component when Built-In-Selftest is failed.
Potential Impact
EPAS full loss of assist.
Set Condition
EPAS ECU SBC device BIST failure at startup.
Clear Condition
EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.