FC_a298_GB_bmsCtrCloseTimeout
FC_a298_GB_bmsCtrCloseTimeout
Alert Information
Charging
critical
<0.01%
Description
The Fast Charge (FC) Electronic Control Unit (ECU) has detected the vehicle pack contactor did not close within the expected 6 second time interval during charging start-up process.
Potential Impact
Charging session may not start.
Set Condition
Vehicle pack contactor does not close within the expected 6 second time frame, resulting in a timeout condition.
Clear Condition
Unplug charge handle.