HVBATT_a014_LsShuntAsicCalNotUsed
HVBATT_a014_LsShuntAsicCalNotUsed
Alert Information
Other
critical
<0.01%
Description
The programmed low side shunt application-specific integrated circuit (ASIC) calibration is not being used for high voltage (HV) current sensing. The default low side shunt ASIC gain will be used and current measurement accuracy may be reduced.
Potential Impact
The default low side shunt ASIC gain will be used for high voltage (HV) current sensing. Low side shunt current measurement accuracy may be reduced.
Set Condition
The stored low side shunt ASIC gain is invalid or the written gain is outside the allowed tolerance.
Clear Condition
The stored low side ASIC gain is valid and the written gain is within the allowed tolerance.