HVBATT_a242_Bp2PackVoltageMismatchFault
HVBATT_a242_Bp2PackVoltageMismatchFault
Alert Information
Other
critical
<0.01%
Description
HVBATT detects that the sum of brick voltages deviates from measured pack voltage.
Potential Impact
Inability to charge, drive, or support the low voltage (LV) system
Set Condition
HVBATT detects that the sum of brick voltages in BP2 deviates from pack voltage by more than 5 percent.
Clear Condition
HVBATT detects that the sum of brick voltages in BP2 is within 5 percent of the measured pack voltage.