HVP_w041_packCtrCloseBlocked
HVP_w041_packCtrCloseBlocked
Alert Information
Battery
warning
<0.01%
Description
Warn if pack contactors are not allowed to close.
Potential Impact
While this alert is set, HV contactors will not be able to close. This will prevent drive, charge and 12V support and eventually the 12V battery will be fully discharged and the vehicle will go offline.
Set Condition
This meta alert will set if any of the reasons for preventing contactors to close (listed in this alert payload) are still present. This alert is always set with an accompanying alert that provides more specific information for the fault.
Clear Condition
Pack contactor blocking condition is cleared